Maintenance for Linear Shaft Guides and Bearings

  1. After cleaning the linear guides, apply liquid‑type bearing lubricating oil to the linear guides, then run the axes back and forth for lubrication. There is no need to remove the bearings.
  2. You may purchase replacement spare parts from us when the bearings are damaged.
  3. Blow off cutting dust from the machine with compressed air after every use. Depending on operating frequency, apply lubricating oil (ordinary clear, low‑viscosity liquid lubricant) to the linear guides and screw rod every two weeks or every month.
  4. ............
Read more

OMIOCNC USB Interface CNC Router Wiring Diagram and Precautions

Follow the diagram to connect your machine to the computer. Key precautions:

  • On a desktop PC, plug the USB cable directly into a rear motherboard port – never use front‑panel ports, extension cables, or USB hubs.
  • Prepare a dedicated PC for the CNC router with only Mach3 installed; disable network access and transfer G‑code via flash drive.
  • Use a PC only – Windows on Mac (native or virtual) is not supported.
  • Place the machine on a heavy, sturdy, and stable table.
  • ............
Read more

Troubleshooting USB disconnection and grounding

 
Troubleshooting USB disconnection and grounding:
 
There are some cases may be leads to instability in the output of electrical impulses.
............
Read more

About Grounding

About Grounding:

Prepare a thick copper wire , one end attached to the foot of the machine working table or any screw of the working table, and the other end connected to the Metal water pipes at home, or nailed a large nail into the ground then connect it to the copper Wire.............

Read more

About cooling water

About cooling water:

  1. The volume of the cooling water tank should be greater than 20L.
  2. You can use a plastic container(barrels) with a lid. Prevent dust falling into the water.
  3. The cooling water temperature should be controlled below 35 degrees Celsius. Use a large capacity water tank can effectively reduce the water temperature.
  4. You can use purified water or tap water as cooling water.
  5. You can add 1% ~ 3% liquid rust to the cooling water (liquid rust for automobile water tank can be used).
  6. The water pump must be completely submerged in the water.
  7. ............
Read more

How to connect limit switch?

see below picture, plug the two wires arbitrarily to A&B pins of switch .

............

Read more

XYZ three-axis cannot move inspection steps

If the XYZ can’t  move:

Step 1. Check whether the red Emergency Stop button on the control box is pressed.

Step 2. Check whether the USB cable is connected to the computer normally, and If your computer is a laptop, you must use its power adapter to power the computer.  Plug the USB cable into other USB port of the computer and then try.

Step 3. Turn on the power switch and check whether the stepper motor is self-locking.  If the stepper motor can be turned by hand, it means that the motor is not self-locking.

Step 4. If the stepper motor is NOT self-locking, turn off the power switch and check the fuse (see attached picture)

Step 5. If there is no problem with the fuse, open the control box, turn on the power switch, and check whether the green light of the power module is on (see attached picture). If the light is not on, the power supply module burnt out.

In addition, if you are a Japanese user, please first test whether your input voltage is stable or greater than 100V. It is recommended that you............